Difference between revisions of "Exit code -1073741510 (0xc000013a)"
(Saving FAQ 175) |
(removing broken link to original faq) |
||
(4 intermediate revisions by 2 users not shown) | |||
Line 1: | Line 1: | ||
− | The message exit code -1073741510 (0xc000013a) means that when you log off of Windows the application gets terminated quite abruptly. Apparently BOINC/the science applications don't like that too much. I understand Vista can shut down in 2 seconds... that's not enough time for BOINC to stop. | + | The message exit code -1073741510 (0xc000013a) means that when you log off of Windows the application gets terminated quite abruptly. Apparently BOINC/the science applications don't like that too much. I understand Vista can shut down in 2 seconds... that's not enough time for BOINC to stop.<br> |
− | + | <br> | |
− | So before you shut down your computer next time, exit BOINC. | + | So before you shut down your computer next time, exit BOINC.<br> |
− | + | * If you run as a normal user install, it's done through Boinc Manager, File->Exit. | |
− | + | * If you run as a service install, you need to stop the service first. Start->Run, type net stop boinc and hit enter. | |
− | + | <br> | |
− | Or: | + | Or:<br> |
+ | <br> | ||
Copy the following text and paste it into the Notepad window, called WaitToKill.reg | Copy the following text and paste it into the Notepad window, called WaitToKill.reg | ||
+ | <br> | ||
+ | Windows Registry Editor Version 5.00 | ||
+ | |||
+ | [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control] | ||
+ | "WaitToKillServiceTimeout"="20000" | ||
− | + | <br> | |
− | + | The 20000 is 20 seconds. Increase/decrease to your liking.<br> | |
− | + | <br> | |
− | + | To add this to the registry double-click the file. The UAC will come up, press continue, press Yes on the next window and OK on the one there-after. You need to reboot to make the changes have effect.<br> | |
− | + | <br> | |
− | The 20000 is 20 seconds. Increase/decrease to your liking. | + | You can also use the following bit of code in a batchfile (.bat).<br> |
− | To add this to the registry double-click the file. The UAC will come up, press continue, press Yes on the next window and OK on the one there-after. You need to reboot to make the changes have effect. | + | Put it in Notepad, save it as Shutdown.bat (make sure the extension is .bat, not .txt)<br> |
− | + | Do change the path between %PROGRAMFILES% if your BOINC lives elsewhere.<br> | |
− | You can also use the following bit of code in a batchfile (.bat). | + | cd %PROGRAMFILES%\BOINC |
− | Put it in Notepad, save it as Shutdown.bat (make sure the extension is .bat, not .txt) | + | boinccmd --quit |
− | Do change the path between %PROGRAMFILES% if your BOINC lives elsewhere. | + | shutdown -s -t 20 |
− | cd %PROGRAMFILES%\BOINC | + | <br> |
− | boinccmd --quit | + | Updating BOINC past 5.10 will fix this error as well.<br> |
− | shutdown -s -t 20 | + | <br> |
− | + | <br> | |
− | Updating | + | {| class="wikitable" style="text-align: center;" |
+ | ! Original writer | ||
+ | ! Original FAQ | ||
+ | ! Date | ||
+ | |- | ||
| Jorden | | Jorden | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
| 175 | | 175 | ||
− | | | + | | 22-05-2008 |
− | | | + | |- |
− | | | + | |} |
Latest revision as of 21:39, 16 August 2017
The message exit code -1073741510 (0xc000013a) means that when you log off of Windows the application gets terminated quite abruptly. Apparently BOINC/the science applications don't like that too much. I understand Vista can shut down in 2 seconds... that's not enough time for BOINC to stop.
So before you shut down your computer next time, exit BOINC.
- If you run as a normal user install, it's done through Boinc Manager, File->Exit.
- If you run as a service install, you need to stop the service first. Start->Run, type net stop boinc and hit enter.
Or:
Copy the following text and paste it into the Notepad window, called WaitToKill.reg
Windows Registry Editor Version 5.00 [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control] "WaitToKillServiceTimeout"="20000"
The 20000 is 20 seconds. Increase/decrease to your liking.
To add this to the registry double-click the file. The UAC will come up, press continue, press Yes on the next window and OK on the one there-after. You need to reboot to make the changes have effect.
You can also use the following bit of code in a batchfile (.bat).
Put it in Notepad, save it as Shutdown.bat (make sure the extension is .bat, not .txt)
Do change the path between %PROGRAMFILES% if your BOINC lives elsewhere.
cd %PROGRAMFILES%\BOINC boinccmd --quit shutdown -s -t 20
Updating BOINC past 5.10 will fix this error as well.
Original writer | Original FAQ | Date |
---|---|---|
Jorden | 175 | 22-05-2008 |