Difference between revisions of "Exit code -1073741510 (0xc000013a)"
(Saving FAQ 175) |
Bowtieguru (talk | contribs) |
||
Line 2: | Line 2: | ||
So before you shut down your computer next time, exit BOINC. | So before you shut down your computer next time, exit BOINC. | ||
− | + | * If you run as a normal user install, it's done through Boinc Manager, File->Exit. | |
− | + | * If you run as a service install, you need to stop the service first. Start->Run, type net stop boinc and hit enter. | |
Or: | Or: | ||
+ | |||
Copy the following text and paste it into the Notepad window, called WaitToKill.reg | Copy the following text and paste it into the Notepad window, called WaitToKill.reg | ||
− | Windows Registry Editor Version 5.00 | + | Windows Registry Editor Version 5.00 |
+ | |||
+ | [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control] | ||
+ | "WaitToKillServiceTimeout"="20000" | ||
− | + | The 20000 is 20 seconds. Increase/decrease to your liking. | |
− | |||
To add this to the registry double-click the file. The UAC will come up, press continue, press Yes on the next window and OK on the one there-after. You need to reboot to make the changes have effect. | To add this to the registry double-click the file. The UAC will come up, press continue, press Yes on the next window and OK on the one there-after. You need to reboot to make the changes have effect. | ||
+ | |||
You can also use the following bit of code in a batchfile (.bat). | You can also use the following bit of code in a batchfile (.bat). | ||
Put it in Notepad, save it as Shutdown.bat (make sure the extension is .bat, not .txt) | Put it in Notepad, save it as Shutdown.bat (make sure the extension is .bat, not .txt) | ||
Do change the path between %PROGRAMFILES% if your BOINC lives elsewhere. | Do change the path between %PROGRAMFILES% if your BOINC lives elsewhere. | ||
− | cd %PROGRAMFILES%\BOINC | + | cd %PROGRAMFILES%\BOINC |
− | boinccmd --quit | + | boinccmd --quit |
− | shutdown -s -t 20 | + | shutdown -s -t 20 |
+ | |||
Updating to BOINC 5.10.45 can also fix this error. It has special code in for Vista to count this as a non-error. | Updating to BOINC 5.10.45 can also fix this error. It has special code in for Vista to count this as a non-error. | ||
+ | |||
+ | |||
+ | |||
| Jorden | | Jorden | ||
| 3 | | 3 |
Revision as of 16:22, 30 June 2016
The message exit code -1073741510 (0xc000013a) means that when you log off of Windows the application gets terminated quite abruptly. Apparently BOINC/the science applications don't like that too much. I understand Vista can shut down in 2 seconds... that's not enough time for BOINC to stop.
So before you shut down your computer next time, exit BOINC.
- If you run as a normal user install, it's done through Boinc Manager, File->Exit.
- If you run as a service install, you need to stop the service first. Start->Run, type net stop boinc and hit enter.
Or:
Copy the following text and paste it into the Notepad window, called WaitToKill.reg
Windows Registry Editor Version 5.00 [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control] "WaitToKillServiceTimeout"="20000"
The 20000 is 20 seconds. Increase/decrease to your liking.
To add this to the registry double-click the file. The UAC will come up, press continue, press Yes on the next window and OK on the one there-after. You need to reboot to make the changes have effect.
You can also use the following bit of code in a batchfile (.bat).
Put it in Notepad, save it as Shutdown.bat (make sure the extension is .bat, not .txt)
Do change the path between %PROGRAMFILES% if your BOINC lives elsewhere.
cd %PROGRAMFILES%\BOINC boinccmd --quit shutdown -s -t 20
Updating to BOINC 5.10.45 can also fix this error. It has special code in for Vista to count this as a non-error.
| Jorden | 3 | 1 | 11:11:16 | 2008-05-22 | 183556 | 1 | 175 | 2008-05-22 11:11:16 | 2008-05-22 11:11:16
|-